This product has been discontinued. For questions or to find a suitable replacement, go to support@tempocom.com
Cat No: KI27624-INGAAS
A Quad Optical Loss Test Set used to test power, insertion loss, continuity and faults on multimode and single mode fiber optic systems at 850 / 1300 nm & 1310 / 1550 nm. In a small package, it provides a powerful optical multi-meter style solution to improve test flexibility and productivity.
The 650 nm VFL Visitester feature on the singlemode source port mixes a VFL in with the test signal during Autotest. In addition to operating as a typical VFL, it gives positive visual identification of a fiber to be connected for loss testing.
| CAT NO | ITEM NO | UPC | Description | IMAGE |
|---|---|---|---|---|
|
FIP100 KIT
|
55504929
|
810025411596
|
Fiber Inspection Probe Kit
| |
|
FIP100 KIT - SC/APC
|
55505321
|
810025417574
|
Fiber Inspection Probe Kit, SC/APC
| |
|
FIP100 KIT -LC/UPC
|
55505322
|
810025417796
|
Fiber Inspection Probe Kit, LC/UPC
| |
|
FIPCC
|
55504932
|
810025411701
|
FIP100 carry case
| |
|
FIPPS
|
55504933
|
810025411831
|
FIP100 power supply with NA, EU, and UK adapters
| |
|
SCUPC BH
|
55504939
|
810025411886
|
SC/UPC Bulkhead Tip
| |
|
LCUPC BH
|
55504940
|
810025411893
|
LC/UPC Bulkhead Tip
| |
|
2.5MMUPC
|
55504941
|
810025411923
|
2.5mm Universal UPC Tip
| |
|
1.25MMUPC
|
55504942
|
810025412166
|
1.25mm Universal UPC Tip
| |
|
SCAPC BH
|
55504943
|
810025412197
|
SC/APC Bulkhead Tip
| |
|
LCAPC BH
|
55504944
|
810025412258
|
LC/APC Bulkhead Tip
| |
|
2.5MMAPC
|
55504945
|
810025412517
|
2.5mm Universal APC Tip
| |
|
1.25MMAPC
|
55504946
|
810025412623
|
1.25mm Universal APC Tip
| |
|
LCUPC BH60 L60
|
55505317
|
810025411176
|
LC/UPC Long Reach 60mm Bulkhead Tip
| |
|
U60 BH
|
55505318
|
810025410896
|
Universal 60 Degree Adapter Bulkhead Tip
| |
|
MPO BH
|
55505319
|
810025419097
|
MPO UPC and APC Bulkhead Tip
| |
|
FIPT ADAPT
|
55505320
|
810025417765
|
Adapter for VIAVI Tips
| |
|
OTAP BH
|
55505177
|
810025412616
|
OptiTap® Bulkhead Tip
|
| Attribute Name | Attribute Value |
|---|---|
| Detector type (meter) | InGaAs |
| Response wavelength (meter) | 600 ~ 1700 nm |
| Calibration wavelengths (meter) | 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm |
| Power range (meter) | +10 ~ -60 dBm (780 ~ 980 nm) / +10 ~ -70 dBm (1270 ~ 1650 nm) |
| Mid-range linearity (meter) | 0.04 dB (typical) |
| Total uncertainty (meter) | 0.3 dB (max) |
| ID tone detection & Autotest sensitivity (meter) | Up to -50 dBm |
| Modulated output (source) | 270 Hz, 1 kHz, 2 kHz ± 2 %, 12 Multi-Fiber ID tones |
| Output wavelength (source) | Port 1: 1310-1550 nm Laser, VisiTester / Port 3: 850, 1300 nm LED |
| Output power (source) | -3 dBm ±1 dB (@ 9/125 µm for 1310, 1550 m) / -20 dBm ±1 dB (@ 62.5/125 µm for 850, 1300 nm) |
| Adjust output power (source) | Adjustable over 7 dB in 0.01 dB steps (for 1310, 1550 nm, VisiTester) / Fixed (for 850, 1300 nm) |
| Wavelength initial tolerance @ 25 °C (source) | 20 nm (for 1310, 1550 nm) |
| Short term stability for 15 min, typical ±2 °C, after warm up, ORL < -25 dB (source) | 0.04 dB (for 1310, 1550 nm) / 0.01 dB (for 850, 1300 nm) |
| Stability over temperature (source) | 0.6 dB (typical for 1310, 1550 nm) / 0.35 dB (typical for 850, 1300 nm) |
| Spectrum width @ FWHM (source) | 3 nm (typical for 1310, 1550 nm) |
| Wavelength drift (source) | 0.4 nm per °C (typical for 850, 1300, 1310, 1550 nm) |
| Mode controlled (source) | 850, 1300 nm (50/125µm compliant: IEC 61280-4-1 {Ed.1.0}, TIA 526-14A & TIA TSB-178) |
| Reconnection repeatability @ 95% confidence (source) | 0.1 dB (for 1310-1550 nm Laser, VisiTester) / 0.05 dB (for 850, 1300 nm LED) |
| VisiTester wavelength | 650 ± 5 nm |
| VisiTester spectrum width @FWHM | 3 nm |
| VisiTester wavelength drift | 0.1 nm per °C |
| VisiTester power | +2 dBm ± 1 dB @ SMF |
| VisiTester laser safety | Class 1, IEC60825-2 |
| VisiTester blink rate (manual) | CW or 2 Hz |
| Accuracy (meter) | 1 % (0.06 dB) |
| Calibration validity (ISO/IEC 17025) | 3 years |
| Resolution (meter) | 0.01 dB |
| Polarization sensitivity (meter) | < 0.05 dB (typical) |
| Autotest | 1-way: compatible with Kingfisher's 1-way Loss Test Sets & Power Meters (except KI9600 series) |
| Tone detection (meter) | 150 ~ 9900 Hz ± 1 % |
| Battery life | Laser/LED source: 90/80 hours (typical) in Autotest |
| Power | Battery / External power via micro-USB |
| Battery type | 2x AA (LR6) Alkaline / 2x AA NiMH AA |
| USB interfaces | micro-USB for power & software / USB-A Flash Drive |
| Auto off | Selectable |
| Software | KITS (free download) |
| Memory | 1,000 four λ tests with date & time / Unlimited on USB Flash Drive |
| Case | Polycarbonate (body) / rubber (edges & corners), moisture resistance, 1-meter drop tested |
| Display size | 74 mm x 55 mm |
| Size | 190 mm x 105 mm x 35 mm |
| Unit weight | 0.42 kg |
| Shipping weight | 1.5 Kg |
| Operating / storage temperature | -15 to 55 °C / -25 to 70 °C |
| Relative humidity | 0 ~ 95 % |
| Warranty | 3 years |